Protective
GE Capacitors for AC Rotating Machines
Surge Protection for AC Generators, Synchronous Condensers
and Large Motors
GE
Protective capacitors offer surge protection for AC generators,
synchronous condensers and large motors.
DIELEKTROL
is the GE non-PCB power capacitor dielectric system, developed
to provide an environmentally acceptable product with
superior performance and reliability.
Protective
capacitors contain a film dielectric and hermetically
sealed bushings, which permit mounting of capacitors in
an upright position or on the side. GE Surge Capacitors
protect the winding insulation by reducing the steepness
of wave fronts applied to or reflected within the machine
windings.
Features
and Benefits
-
Surge protection for AC Generators, synchronous condensers
and large motors
-
Time proven GE HAZY film foil dielectric system
-
DIELECTROL Non-PCB insulating fluid
-
Provides Turn-to-Turn insulation protection by reducing
steepness of wave fronts applied to or reflected within
the machine
- Used
in combination with TRANQUELL station arresters for
optimum protection
-
Protective capacitors contain a film dielectric and
hermetically sealed bushings, which permit mounting
of capacitors in an upright position or on the side.
- Altitude:
0 to 18,000 feet
Fixed
Motor and Pump Capacitors (Type GEM OFW)
Outdoor Weatherproof, 1-15 kVAR 240 Volts, 1-30 kVAR 480
Volts, Three-phase Delta, 60 Hertz
These
Type GEM capacitors are designed primarily for the motor
requirements of oil field and other pumping installations.
Their application, however, may be extended to other motor
applications installed indoor or outdoor. Type GEM OFW
capacitors feature multiple cells which are assembled
in parallel in a NEMA 3 enclosure. Each capacitor cell
features the patented GE Pressure Sensitive Interrupter
(PSI) that protects against cell rupture. The metallized
polypropylene film dielectric system provides an instantaneous
self-healing action and greatly reduced energy losses.
Discharge
resistors are included to reduce voltage to 50 volts or
less within one minute of de-energization. A 4 ft., 4-conductor
flexible cable is provided for easy installation.
Type
GEM capacitors offer high reliability and long life. They
are suitable for operation over a temperature range of
–40°C to +46°C. GEM also features Dielektrol
impregnant which is a biodegradable Class IIIB combustible
fluid.
Fixed
Low Voltage Power Factor Correction Capacitors
Enclosed Indoor Dustproof NEMA 12 and Outdoor Weatherproof
NEMA 3
Single Phase or 3-Phase, 1.0-500 kVAR, 60 Hertz, 240,
480, 600 Volts
Type
GEM Capacitors feature multiple cells which are assembled
in parallel in an enclosure suitable for both indoor and
outdoor applications, (NEMA 12 and NEMA 3). Each capacitor
cell features the patented GE Pressure Sensitive Interrupter
(PSI) that protects against cell rupture. The metallized
polypropylene film dielectric system provides an instantaneous
self-healing action and greatly reduced energy losses.
GEM capacitors include discharge resistors to reduce voltage
to 50 volts or less within one minute of de-energization.
GEM also features Dielektrol impregnant which is a biodegradable
Class IIIB combustible fluid.
GEM
capacitors offer high reliability and long life. They
are suitable for operation over a temperature range of
–40°C to +46°.
The
GEM assemblies are UL Listed and CSA labeled.
Automatic
Fast-Switching LV Power Factor Correction Capacitors
GEMATIC Quick Response
Fast
Response, Transient-Free Reactive Power Compensation Systems
- Ultra
Fast Response (UFR): A real-time, transient-free system
used
to compensate extremely rapid loads within one cycle
(typically
5-16 mSec).
-
Fast Response (FR): A fast, transient-free system, used
to compensate
any load within 3-4 seconds.
Advantages
-
Ultra Fast Response (UFR) and Fast Response (FR):
- Transient-free
capacitor group switching, using electronic switching
elements
-
Prevent damage to sensitive electronic equipment
-
Saves energy
-
Harmonic filtration
- Accurate
power factor control, even in the presence of harmonics
-
Dramatically increases the life expectancy of switching
elements and capacitors
-
Considerably lower temperature rise of capacitors
and inductors due to unique scan feature
-
Built-in three phase network analyzer, measuring
all network parameters including harmonics
-
Unique self-testing and comprehensive reporting
feature
-
Power IQ
-
Ultra Fast Response (UFR) (in addition to the above):
-
Cycle-by-cycle reactive power compensation (total
acquisition time of 5-16 mSec)
-
Prevents voltage drop and flickering
-
Used for Real Time applications, such as spot welding
and motor start-up
-
Enhances capacity of local generator systems, such
as diesel and windmill generators
-
Combination of one to three single-phase systems
available for unbalanced loads
Automatic
LV Power Factor Correction Capacitors
Type GEMATIC Compact and GEMATIC Select, Three-phase,
60 Hertz, 240, 480, 600 Volts
GEMATIC
multi-step power factor control equipment automatically
maintains desired power factor level, adjusting to system
load requirements in selected kVAR steps. The solid-state
control responds to a current signal from the optional
current transformer and to a voltage signal from a potential
transformer included in the equipment.
GEMATIC
equipments feature capacitors with a metallized dielectric
system providing a self-healing action and reduced energy
losses. The biodegradable impregnant is a class IIIB combustible
fluid. Discharge resistors reduce the voltage to 50 volts
or less within one minute of de-energization. The capacitor
cells are 3 phase and are designed for 110% of rated voltage,
135% of rated current, and, 135% of rated kVAR.
The
power factor controller requires a CT signal for operation.
The CT primary should be sized for the total phase current
to be compensated (capacitor current and load current).
Typically, the total phase current should be 50% to 80%
of the CT primary rating. The CT secondary is rated 5A.
The CT is connected to one phase of the equipment and
the factory installed PT is connected across the other
two phases.
Fixed
MV Power Factor Correction Capacitors
Enclosed Indoor Dustproof and Outdoor Weatherproof, 25-900
kVAR, 60 Hz, 2400, 4160, 4800 Volts, 1.0-200 kVAR, 240
Volt
Type
HWT equipments are suitable for use on indoor or outdoor
primary circuits where small amounts of kVAR are required.
They may be installed at load centers or directly at the
terminals of 2300 and 4000 volt motors. Permissible ambient
temperatures are –40° to +45°C. Discharge
resistors in each capacitor reduce the voltage to 50 volts
or less within 5 minutes of de-energization.
Type
HWT equipments contain less than three gallons of flammable
liquid in a single container and therefore do not require
installation in a vault to meet the NEC.
High
Voltage Capacitor Units, Single and Three-Phase
(Film/Foil Designs w/Dielektrol), 50-600 kVAR, 60 Hertz,
2400-24,940 Volts
Film/Foil
Dielektrol is the GE non-PCB low loss power capacitor
dielectric system, developed to provide lower operating
costs and greatly enhanced fuse coordination for the prevention
of case ruptures. The Dielektrol insulating liquid is
a Class IIIB combustible fluid.
- These
capacitors are designed to meet ANSI Std 18.
-
CSA labeling available upon request.
High
Voltage Pole-Mounted, Open Stack-Rack and Metal Enclosed
Equipment
Pole-type Equipment, 150-3600 kVAR, 60 Hertz,
Open Stack-rack Banks, 1200 kVAR and above, 60 Hertz
Metal Enclosed, 2.4 through 38kV, 150 kVAR and above
Pole
Mounted Equipment Description
These equipments are pre-wired, factory assembled, and
shipped ready for pole installation with single-phase
units. Racks are of welded structural aluminum and are
suitable for mounting switches and junction box and cable
assembly. Lightning arresters and/or potential transformers
can also be mounted.
Open
Stack-Rack Equipment Description
This application is most popular for large blocks of three-phase
Kilovar. Capacitor units and individual fuses are installed
in welded aluminum racks, either upright or edgemount.
Racks are shipped ready for field installation with base
and inter-rack insulators, substructure, interconnecting
bus wire and other accessories for a three-phase equipment.
Metal
Enclosed Equipment Description
These power factor correction equipments are metal enclosed
for indoor and outdoor installations. These banks can
be located on a distribution feeder as a small padmount
or at the workstation site.Banks are shipped ready for
installation. Banks can be provided with the following
options: oil or vacuum switching, automatic control and
protection, stainless steel housing, custom colors, key
mechnical or electrical interlocks, capacitor removal
device, NEMA 1, 3R, 4, 4X or 12 enclosures.
For
more information on GE Capacitors, please e-mail our sales
dept at sales@jostfewkes.com
or utilize our Quotation
Request Form. |